Most checklists online are invented. This one is the rule an Oregon inspector is actually held to, item by item, with the citation beside each.

Where this checklist comes from

Oregon adopts a standard of practice for home inspections in OAR chapter 812, division 8, rules 812-008-0200 through 812-008-0214. It is law, not guidance. An inspector working to that standard must address every listed item in a written report, and OAR 812-008-0202 states it is not sufficient to hand over a report listing only deficiencies.

So the useful checklist is not somebody's opinion of what matters. It is the ten system categories the rule names, plus the exclusions that decide what you have to arrange yourself.

The rule

What the inspector must examine

Ten system categories, each its own rule in division 8. Ask for any of these by number.

812-008-0205 Structural components Foundation, framing and floors, limited to visible components.
812-008-0206 Exterior and site Cladding, trim, grading and drainage adjacent to the building.
812-008-0207 Roofing Covering, drainage, flashings and penetrations.
812-008-0208 Plumbing Supply, drainage, fixtures and water heating. Above ground oil storage only.
812-008-0209 Electrical Service, panels, branch wiring and a representative sample of devices.
812-008-0210 Heating The permanently installed heating system and its distribution.
812-008-0211 Central air conditioning Central systems only. Window and non-central units are excluded.
812-008-0212 Interiors Walls, ceilings, floors, steps, railings, doors and windows.
812-008-0213 Insulation and ventilation Attic and crawlspace insulation and the ventilation serving them.
812-008-0214 Built-in kitchen appliances Permanently installed appliances only.
OAR 812-008-0204

What an inspector is not required to report

This list settles most post-inspection disputes, and almost no consumer-facing checklist reproduces it.

  • Life expectancy of components
  • Causes of needed repairs
  • Methods, materials or costs of correction
  • Suitability for specialized use
  • Code compliance
  • Advisability of purchase
  • Presence or absence of pests, wood-damaging organisms, rodents or insects
  • Cosmetic items
  • Underground items
  • Non-permanently installed items
  • Detached structures
Verified fields
Scope limit
text
Inspections undertaken in accordance with division 8 are visual and are not technically exhaustive.
rule text verbatim
Inspections undertaken in accordance with division 8 are visual and are not technically exhaustive.
Underground exclusion
text
Inspectors are not required to report on cosmetic items, underground items, or items not permanently installed.
Oil storage limit
text
The plumbing standard covers only ABOVE GROUND oil storage.
Structural limit
text
Structural scope is limited to VISIBLE structural components.
Heating oil tanks
why outside
Underground items are excluded, and the oil storage standard reaches only above-ground tanks.
page
/issues/decommissioned-oil-tanks
specialist
DEQ-licensed service provider
Sewer laterals
why outside
Underground items are excluded, and the inspection is visual and not technically exhaustive.
page
/issues/sewer-scope-clay-laterals
specialist
Sewer scope contractor
Radon
why outside
Inspectors are not required to determine the presence of environmental hazards or contaminants.
page
/issues/radon-testing-oregon
specialist
NRPP or NRSB certified measurement technician, since Oregon does not licence them
Seismic condition below the surface
why outside
Structural scope is limited to visible components, so concealed connections, hold-downs and foundation reinforcement are out.
page
/issues/seismic-retrofit
specialist
Engineer, or a retrofit contractor working to Portland's prescriptive standard
How to use it
type pages
Every /types/ page should state its exclusions from OAR 812-008-0204 rather than from a trade association's version.
Related
general exclusions full list